SIPLUS SB 1223 信號板
Overview
●數字量輸入和輸出作為 SIPLUS S7-1200-CPU 的集成 I/O 的補充
●可直接插入 CPU (不可用于 +70 °C 版本中)
注意:
SIPLUS extreme 產品是基于西門子工業標準產品的。此處列出的內容來自相關的標準產品。添加了特定 SIPLUS extreme 信息
Area of application
SB 1223 數字量輸入/輸出信號模塊允許:
●將控制器與過程中的數字信號連接
●將數字信號從控制器輸出到過程。
Design
信號板直接插到每個 S7-1200 CPU 前面的插座中。
●安裝:
信號板直接插到 SIMATIC S7-1200 CPU 中,因此可以電氣、機械地連接到 CPU
●CPU 的安裝尺寸保持不變
●由于所有信號板均配備可拆卸的連接端子(“獨立接線”),所以更換方便。
Functions
SB 1223 數字量輸入/輸出信號板
●將過程中的外部數字信號電平轉換為 S7-1200 的內部信號電平,
●還可將 S7-1200 的內部信號電平轉換為過程所需的外部信號電平
Technical Specifications
●min.
Order number | 6AG1223-0BD30-4XB0 | 6AG1223-0BD30-5XB0 | 6AG1223-3AD30-5XB0 | 6AG1223-3BD30-5XB0 |
---|---|---|---|---|
SIPLUS S7-1200 SB1223 2DI / 2DO | SIPLUS S7-1200 SB1223 2DI/2DO | SIPLUS S7-1200 SB1223 2DI/2DQ, 5VDC | SIPLUS S7-1200 SB1223 2DI/2DQ, 24VDC | |
Product type designation | ||||
Supply voltage | ||||
permissible range, lower limit (DC) | 20.4 V | 20.4 V | ||
permissible range, upper limit (DC) | 30 V | 30 V | ||
Input current | ||||
from backplane bus 5 V DC, typ. | 50 mA | 50 mA | 50 mA | 50 mA |
Output voltage | ||||
Power supply to the transmitters | ||||
| 4 mA; per channel | 4 mA; per channel | 4 mA; per channel | 4 mA; per channel |
Power loss | ||||
Power loss, typ. | <1 W | 1 W | 1 W | 1 W |
Digital inputs | ||||
Number of digital inputs | 2; Current-sinking | 2; Current-sinking | 2; Current-sourcing | 2; Current-sourcing |
| 1 | 1 | 1 | 1 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes | Yes | Yes |
Number of simultaneously controllable inputs | ||||
all mounting positions | ||||
| 2 | 2 | 2 | 2 |
Input voltage | ||||
| DC | DC | ||
| 24 V | 24 V | 5 V | 24 V |
| 0 to 5 V | 0 to 5 V | 0 to 1 V | 0 to 5 V |
| +15 to +30V | +15 to +30V | 2 to 6 V | +15 to +30V |
Input current | ||||
| 1 mA | 1 mA | 3 mA | 2 mA |
| 6 mA | 5.8 mA | ||
| 0.5 A | 0.5 A | 14 mA | |
Input delay (for rated &#118alue of input voltage) | ||||
for standard inputs | ||||
| Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
| 2 μs | 2 μs | 2 μs | 2.5 μs |
| 10 μs | 10 μs | ||
for interrupt inputs | ||||
| Yes | Yes | Yes | Yes |
for counter/technological functions | ||||
| Yes | Yes | Yes | Yes |
Cable length | ||||
| 500 m | 500 m | 50 m | Standard input: 500 m, high-speed counters: 50 m |
| 300 m | 300 m | ||
Digital outputs | ||||
Number of digital outputs | 2; MOSFET, solid-state (current-sinking/current-sourcing) | 2; MOSFET, solid-state (current-sinking/current-sourcing) | 2; MOSFET, solid-state (current-sinking/current-sourcing) | 2; MOSFET, solid-state (current-sinking/current-sourcing) |
| 1 | 1 | 1 | 1 |
short-circuit protection | No | No | No | No |
Switching capacity of the outputs | ||||
| 0.5 A | 0.5 A | 0.1 A | 0.1 A |
| 5 W | 5 W | ||
Load resistance range | ||||
| 0.6 &#8486; | 0.6 &#8486; | 5 &#8486; | 10 &#8486; |
Output voltage | ||||
| 24 V | 24 V | 5 V | 24 V |
| 0.1 V; with 10 kOhm load | 0.1 V; with 10 kOhm load | 0.4 V | 0.1 V; with 10 kOhm load |
| 6 V | |||
Output current | ||||
| 0.5 A | 0.5 A | 0.1 A | 0.1 A |
| 0.11 A | |||
| 10 μA | 10 μA | 10 μA | |
Cable length | ||||
| <500 m | 500 m | 50 m | 50 m |
| 150 m | 150 m | ||
Interrupts/diagnostics/status information | ||||
Alarms | ||||
| Yes | Yes | Yes | Yes |
Diagnostic messages | ||||
| Yes | Yes | Yes | Yes |
Diagnostics indication LED | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Degree and class of protection | ||||
Degree of protection acc. to EN 60529 | ||||
| Yes | Yes | Yes | Yes |
Standards, approvals, certificates | ||||
CE mark | Yes | Yes | ||
Ambient conditions | ||||
Free fall | ||||
| 0.3 m; five times, in dispatch package | 0.3 m; five times, in dispatch package | 0.3 m; five times, in dispatch package | 0.3 m; five times, in dispatch package< |
Ambient temperature during operation | ||||
0 °C; = Tmin | -25 °C; = Tmin | -25 °C; = Tmin | -25 °C; = Tmin | |
| 55 °C; = Tmax | 55 °C; = Tmax | 55 °C; = Tmax | 55 °C; = Tmax |
Ambient temperature during storage/transportation | ||||
| -40 °C | -40 °C | -40 °C | -40 °C |
| 70 °C | 70 °C | 70 °C | 70 °C |
Extended ambient conditions | ||||
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | ||||
| 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | ||||
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Mechanics/material | ||||
Type of housing (front | ||||
| Yes | Yes | Yes | Yes |
Dimensions | ||||
Width | 38 mm | 38 mm | 38 mm | 38 mm |
Height | 62 mm | 62 mm | 62 mm | 62 mm |
Depth | 21 mm | 21 mm | 21 mm | 21 mm |
Weights | ||||
Weight, approx. | 40 g | 40 g | 40 g | 40 g |
詳細產品信息請訪問:https://mall.industry.siemens.com/mall/zh/cn/Catalog/Products/10049381?tree=CatalogTree